CDGZT - PAINT THINNER, MINERAL SPIRITS

  • MSDS: CDGZT
  • Manufacturer: HOME OIL CO
  • Product Name: PAINT THINNER, MINERAL SPIRITS
  • National Stock Number: 8010-00-558-7026
Product Identification

Product ID:PAINT THINNER, MINERAL SPIRITS
MSDS Date:09/01/1994
FSC:8010
NIIN:00-558-7026
MSDS Number: CDGZT

Responsible Party
HOME OIL CO
3511 N OHIO
WICHITA, KS 67201
US

Emergency Phone: 316-838-4663

Info Phone: 316-832-1211

Cage: 0A9L8

Contractor
HOC INDUSTRIES, INC
2609 WICHITA, KS 67219 US

Telephone: 316-838-4663

Cage: 0A9L8

Ingredients

MIXTURE OF C9-C12 ALIPHATIC

CAS: 64742-88-7

Fraction By Weight: 100.0%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


BENZENE (SARA 313) (CERCLA)

CAS: 71-43-2

RTECS: CY1400000

Fraction By Weight: .1-.9%

OSHA PEL 1 PPM/5PPM STEL

ACGIH TLV: 10 PPM

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


VOC = 778G/L

RTECS: 9999999VO

OSHA PEL NOT RELEVANT

ACGIH TLV: NOT RELEVANT

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: MAY CAUSE IRRIT.
EXPERIENCED AS DISCOMFORT & SEEN AS EXCESS REDNESS & SWELLING OF
THE EYE. SKIN: PROLONGED OR WIDESPREAD SKIN CONTACT MAY RESULT IN
ABSORPTION OF POTENTIALLY HARMFUL AMTS OF MATL. CHRONIC CONTACT
W/CLOTHING WETTED W/MATLMAY SEVERE IRRIT & DISCOMFORT. INHAL:
OVEREXPOSURE TO MIST
Effects of Overexposure:VAPORS MAY CAUSE
DIZZINESS/DROWSINESS/HEADACHE/NAUSEA. OVEREXPOSURE MAY CAUSE
UNCONSCIOUSNESS. INGEST: MAY IRRIT STOMACH & INTESTINES. MAY BE
ASPIRATED INTO LUNGS IF SWALOWED CAUSING PULMONARY EDEMA & CHEM
PNEUMONITIS.

First Aid

First Aid:EYES: FLUSH THOROUGHLY W/WATER >15 MIN. GET MED AID. SKIN:
WASH EXPOSED AREA W/SOAP & WATER. IF IRRIT DEVELOPS GET MED AID.
INGEST: DO NOT INDUCE VOMITING. CALL DR. IMMED. INHAL: GET FRESH
AIR. IF NOT BREATHING, GIVE MOUTH TO MOUTH ARTIFICIAL RESPIRATION.
INHALATION OF VAPORS/MIST MAY RESULT IN THE ABSORPTION OF
POTENTIALLY HARMFUL AMOUNTS OF MATERIAL.

Fire Fighting

Flash Point Method:TCC
Flash Point:105F,41C
Autoignition Temp:Autoignition Temp Text:NE
Extinguishing Media:USE DRY CHEM, FOAM OR CARBON DIOXIDE.
Fire Fighting Procedures:EVACUATE AREA, SHUT OFF SOURCE IF POSSIBLE.
WATER FOG OR SPRAY SHOULD BE USED TO KEEP FIRE EXPOSED CNTNRS /EQPT
COOL. DON'T SPRAY WATER DIRECTLY ON FIRE. *

Accidental Release

Spill Release Procedures:REMOVE IGNIT SOURCES. VENT AREA, AVOID
BREATHING VAPOR. USE AIR SUPPLIED MASK FOR LG SPILLS OR IN CONFINED
AREAS. CONTAIN SPILL. REMOVE W/INERT ABSORBENT. AVOID CONTACT
W/EYES. DON'T ALLOW PROD TO ENT ER STREAMS/SEWERS.

Handling

Handling and Storage Precautions:TRANSPORT/HANDLE/STORE ACCORDING TO
OSHA 1910.106 & APPLIC DOT REGS. GROUND & ELECTRICALLY INTERCONNECT
CNTNRS FOR TRANSFER. USE SPARKPROOF TOOLS.
Other Precautions:DANGER! FLAMMABLE. CAUSES MILD IRRIT TO EYES/SKIN.
KEEP AWAY FROM HEAT/SPARKS/FLAME. KEEP CNTNR CLSD. AVOID SKIN/EYE
CONTACT. USE ONLY IN WELL ENT AREAS. AVOID BREATHING VAPOR/MIST.
KEEP HEAD AWAY FRO M CNTNR WHEN OPEN/DISPENSING. WASH **

Exposure Controls

Respiratory Protection:IF VAPOR, MIST OR DUST IS GENERATED IN EXCESS OF
PERMISSIBL E CONCENTRATIONS, USE RESP APPROVED BY OSHA OR NIOSH.
Ventilation:LOCAL EXHAUST VENT RECOMMENDED. EXPOSURE LIMIT IS 400 PPM.
Protective Gloves:CHEM/PETROLEUM DISTILLATE RESISTANT.
Eye Protection:CHEM GOGGLES, NO CONTACT LENSES.
Other Protective Equipment:PROTECTIVE CLOTHING SUCH AS UNIFORMS SHOULD
BE WORN..NK
Work Hygienic Practices:**WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:321 TO 373F
Vapor Pres:2.7 @ 68F
Vapor Density:4.8
Spec Gravity:0.78 @ 60F
Viscosity:NE
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:COLORLESS, HYDROCARBON ODOR.
Percent Volatiles by Volume:100.0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NK.
Hazardous Decomposition Products:PRODUCTS EVOLVED WHEN SUBJECT TO HEAT
OR COMBUSTION: CARBON OXIDES MAY BE FORMED ON BURNING.

Disposal

Waste Disposal Methods:INCINERATE OR PLACE IN RCRA PERMITTED WASTE
MANAGEMENT FACILITY. IN CASE OF BREAKAGE OR LEAKAGE CALL PERS
1-800-633-8253. D001.

======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.